Abstract

Objective: The aim of our study is to determine and evaluate all factors that may affect the health and safety of the employees, considering the dangers arising from the working conditions in the workplaces, the materials, machinery and installations used, human and organizational errors, and to prepare a guide for controlling the risks.

Methods: Within the scope of the research, in addition to the internet web-based data, the statements of a total of six authorized individuals (two employees from each unit) working in the specified units were used. The team carrying out the risk assessment study, employers, occupational safety specialists who carry out health and safety services in the workplace, occupational physicians, laboratory managers, employees who are determined to represent all units in the study and who have information about the current or potential sources of the danger and risks.

Results: The risk of infection transmission and noise risk due to not paying attention to the use of personal protective equipment in the microbiology laboratory were found to be high risks. All risks in the sterilization unit were determined as medium risks. The risk of giving the wrong blood product to the patient in the blood transfusion center was found to be a high risk.

Conclusion: Attention should be paid to the use of personal protective equipments, barcoding of patient samples should be considered, and devices should be maintained on time. High-risk situations should be reduced to medium, and employees should be trained on the risk assessment procedures.

Keywords: Blood transfusion unit, medical microbiology laboratory, risk analysis, sterilization unit

References

  1. Azadeh A, Fam IM, Khoshnoud M, Nikafrouz M, Nouri J. Design and implementation of a fuzzy expert system for performance assessment of an integrated health, safety, environment (HSE) and ergonomics system: The case of a gas refinery. Inform Sci. 2008;178(22):4280- 300. https://doi.org/10.1016/j.ins.2008.06.026
  2. Eidesen K, Sollid SJM, Aven T. Risk assessment in critical care medicine: A tool to assess patient safety. J Risk Res. 2009;12(3-4):281-94. https://doi.org/10.1080/13669870802456914.
  3. Sewell DL. Laboratory-acquired infections: Are microbiologists at risk? Clin Microbiol Newsl. 2006;28(1):1-6. https://doi.org/10.1016/j.clinmicnews.2005.12.004
  4. Dehnavieh R, Ebrahimipour H, Molavi-Taleghani Y, Vafaee-Najar A, Noori Hekmat S, Esmailzdeh H. Proactive risk assessment of blood transfusion process, in pediatric emergency, using the Health Care Failure Mode and Effects Analysis (HFMEA). Glob J Health Sci. 2015;7(1):322-31. https://doi.org/10.5539/gjhs.v7n1p322
  5. Nichols JH. Laboratory quality control based on risk management. Ann Saudi Med. 2011;31(3):223-8. https://doi.org/10.4103/0256-4947.81526
  6. McGowan J, Wojahn A, Nicolini JR. Risk management event evaluation and responsibilities. StatPearls. Treasure Island (FL): StatPearls Publishing; 2022. [https://www.ncbi.nlm.nih.gov/books/NBK559326](Erşim tarihi: Ocak 2022).
  7. Türk M. Bir üniversite hastanesi mikrobiyoloji laboratuvarında risk değerlendirilmesi. Mesleki Sağlık ve Güvenlik Dergisi. 2012;12(43):27-33.
  8. Koroglu M, Altındiş S, Aydemir Ö, Yuksel B. Mikrobiyoloji laboratuvarlarında çalışan güvenliği ve biyogüvenlik uygulamaları açısından Türkiye’de çok merkezli bir değerlendirme. Mikrobiyol Bul. 2020;54(3):347-67. https://doi.org/10.5578/mb.69634
  9. Demirkan C. Sağlık hizmetleri sektöründe risk değerlendirmesi: Hastane merkez laboratuvarı örneği [Tıpta uzmanlık tezi]. Edirne: Trakya Üniversitesi, 2015.
  10. Karabulut C, Canbaz B, Kandemir G. Merkezi sterilizasyon ünitesinde çalışanlarda iş sağlığı ve güvenliği uygulamaları ve risk değerlendirme çalışması. J Med Sci. 2021;2(3):32-41. https://doi.org/10.46629/JMS.2021.46
  11. Dağlı G. Merkezi sterilizasyon ünitesi çalışanlarının güvenliği, ünitede korunma ve örgütlenme modelleri. 5. Ulusal Sterilizasyon Dezenfeksiyon Kongresi, 4-8 Nisan, 2007, Dezenfeksiyon Antisepsi Sterilizasyon Derneği, Antalya.
  12. Bolcato M, Russo M, Trentino K, Isbister J, Rodriguez D, Aprile A. Patient blood management: The best approach to transfusion medicine risk management. Transfusion and apheresis science. 2020;59(4):102779. https://doi.org/10.1016/j.transci.2020.102779
  13. Cagliano AC, Grimaldi S, Rafele C. A structured approach to analyse logistics risks in the blood transfusion process. J Healthc Risk Manag. 2021;41(2):18-30. https://doi.org/10.1002/jhrm.21458
  14. Chadrashekar S, Kanthraraj A. Risk mitigation in blood transfusion services – A practical approach at the blood center level. Glob J Transfus Med. 2019;4(2):132-9. https://doi.org/10.4103/GJTM.GJTM_58_19

How to cite

1.
Derçin K, Küçük B, Kaya E, Doğan NF, Aral M. Risk Assessment in Medical Microbiology Laboratory, Blood Transfusion Center and Central Sterilization Unit. Turk Mikrobiyol Cemiy Derg. 2023;53(1):10-20. https://doi.org/10.54453/TMCD.2023.16046