Abstract

Objective: More than 70% of medical laboratory errors occur in the pre-analytical phase. Analysis and recording of errors are necessary for evaluation and prevention of errors. We aimed to evaluate the phases of pre-analytical errors of microbiology laboratory and classify them according to six sigma approaches.

Material and Methods: Samples which were considered inappropriate for the analysis at the medical microbiology laboratory were evaluated under the three headings as error categories, hospital units and laboratory areas where the analyses were done. Error ratio in one million was determined, and expressed on a sigma scale. The calculated sigma values were classified as follows: very good, ≥5.0; good, 4.0-5.0; minimum, 3.0 and

Results: There were no unacceptable or minimum errors according to sigmametric evaluation. Samples that were evaluated as having a sigma value of ≥5.0 according to error categories were clotted, lipemic, inadequate samples, samples collected in inappropriate containers, faulty barcodes, and those sent from units of serologic analysis. Those with a sigma value between 4.0Conclusion: Continuous data analysis is nidispesable for controlling preanalytic phase errors. Continuity of education on the preanalytical phase and strengthening the technologic infrastructure are fundamental factors in the control of this phase.

Keywords: Preanalytical phase, microbiology, sigmametric evaluation

References

  1. Aksay K, Orhan F, Kurutkan MN. Sağlık hizmetlerinde bir risk yönetimi tekniği olarak FMEA: Laboratuvar sürecine yönelik bir uygulama. Sağlıkta Performans ve Kalite Dergisi. 2012;4(2):121-42.
  2. Gajjar M, Patel A, Jain S. Monitoring of quality indicators in pre analytical phase of testing in the clinical biochemistry laboratory of a tertiary care hospital attached with Government Medical College. IOSR- JDMS. 2016;15(7):62-8. http://doi.org/10.9790/0853-150756268
  3. Hammerling JA. A review of medical errors in laboratory diagnostics and where we are today. Lab Med. 2012;43(2):41-4. http://doi.org/10.1309/LM6ER9WJR1IHQAUY
  4. Plebani M, Sciacovelli L, Aita A, Padoan A, Chiozza ML. Quality indicators to detect pre-analytical errors in laboratory testing. Clin Chim Acta. 2014;432:44-8. http://doi.org/10.1016/j.cca.2013.07.033
  5. Coşkun A, Ünsal İ, Serteser M, Inal T. Six sigma as a quality management tool: Evaluation of performance in laboratory medicine, quality management and six sigma, Abdurrahman Coskun (Ed.), InTech. https://www.intechopen.com/books/quality-management-and-six-sigma/six-sigma-as-a-quality-management-tool-evaluation-of-performance-in-laboratory-medicine.(Erişim Tarihi: Mart 2018) http://doi.org/10.5772/9928
  6. Grecu DS, Vlad DC, Dumitrascu V. Quality indicators in the preanalytical phase of testing in a stat laboratory. Lab Med. 2014;45(1):74-81. http://doi.org/10.1309/LM9ZY92YBZRFPFQY
  7. Green SF. The cost of poor blood specimen quality and errors in preanalytical processes. Clin Biochem. 2013;46(13-14):1175-9. http://doi.org/10.1016/j.clinbiochem.2013.06.001
  8. Lippi G, Blanckaert N, Bonini P, et al. Haemolysis: an overview of the leading cause of unsuitable specimens in clinical laboratories. Clin Chem Lab Med. 2008; 46(6):764-72. http://doi.org/10.1515/CCLM.2008.170
  9. Söderberg J, Jonsson PA, Wallin O, Grankvist K, Hultdin J. Haemolysis index-an estimate of preanalytical quality in primary health care. Clin Chem Lab Med. 2009;47(8):940-4. http://doi.org/10.1515/CCLM.2009.227
  10. Avcı E, Çeken N, Kangal Z, et al. Approach to pre-analytical errors in a public health laboratory. Turk J Biochem. 2017;42(1):59-63. http://doi.org/10.1515/tjb-2016-0197
  11. Özcan O, Güreser AS. Tetkik öncesi hata kaynakları ve eğitim. Dicle Tıp Derg. 2012;39(4):524-30. http://doi.org/10.5798/diclemedj.0921.2012.04.0194
  12. Yaylı G, Ergin Ç, Gülen H. Bakteriyolojik kültürlerde kontaminasyonun mali analizi. Klimik Derg. 2001;14(3):154-8.
  13. Chawla R, Goswami B, Tayal D, Mallika V. Identification of the types of preanalytical errors in the clinical chemistry laboratory: 1-Year Study at G.B. Pant Hospital. Lab Med. 2010;41(2):89-92. https://doi.org/10.1309/LM9JXZBMLSVJT9RK
  14. Öz L, Koçer D, Buldu S, Karakükcü Ç. Kayseri Eğitim ve Araştırma Hastanesi Klinik Biyokimya Laboratu-varında pre-preanalitik hataların analizi. Türk Klinik Biyokimya Derg. 2017;15(3):119-28.

How to cite

1.
Çeken N, Avcı E, Duran H. Sigmametric Evaluation of Preanalytical Errors in a Medical Microbiology Laboratory. Turk Mikrobiyol Cemiy Derg. 2018;48(2):141-146. https://doi.org/10.5222/TMCD.2018.141