Abstract
Hospitals are major risk environments for Legionnaires' disease. Prevention of the disease requires implementation of a systematic program involving active case surveillance in conjunction with the risk assessment in the hospital. Searching the presence of Legionella in the hospital water system is considered as one of the risk assessments in the hospitals. To obtain significant results from the Legionella search process, it is of crucial importance to take samples which best represent the plumbing system. The procedure used for the laboratory analysis of samples also should allow successful isolation of the culprit bacteria. In this article, basic principles of Legionella investigation in the plumbing systems are summarized so as to keep the hospital-associated Legionnaires' disease under control.
Keywords: Legionnaires' disease, nosocomial infection, water microbiology
References
- Ostergaard L, Anderson PL. Etiology of community-acquired pneumonia. Evaluation by transtracheal aspiration, blood culture or serology. Chest 1993; 104:1400-7. http://dx.doi.org/10.1378/chest.104.5.1400
- Stout JE, Yu VL, Muraca P, Joly J, Troup N, Tompkins LS. Potable water as a cause of sporadic cases of community-acquired Legionnaires’ disease. N Engl J Med 1992; 326:151-5. http://dx.doi.org/10.1056/NEJM199201163260302 PMid:1727545
- Marrie TJ, De Carolis E, Yu VL, et al. Legionnaires’ disease - results of a multicentre Canadian study. Can J Infect Dis 2003; 14:154-8.
- Yu VL. Nosocomial legionellosis. Curr Opin Infect Dis 2000; 13:385-8. http://dx.doi.org/10.1097/00001432-200008000-00010
- Sopena N, Sabrià M, Neunos 2000 Study Group. Multicenter study of hospital-acquired pneumonia in non-ICU patients. Chest 2005; 127:213-9. http://dx.doi.org/10.1378/chest.127.1.213 PMid:15653986
- Vergis EN, Akbas E, Yu VL. Legionella as a cause of severe pneumonia. Semin Respir Crit Care Med 2000; 21:295-304. PMid:16088740
- Seyahat İlişkili Lejyoner Hastalığı Kontrol Programı Genelgesi. Sağlık Bakanlığı, TSHGM, 01.05.2001-34.
- Bulaşıcı Hastalıkların Bildirimi Sistemi Yönergesi (Bulaşıcı Hastalıkların İhbarı ve Bildirim Sistemi, Standart Tanı, Sürveyans ve Laboratuvar Rehberi-2004). Sağlık Bakanlığı, TSHGM, 24.02.2004-1534.
- Schlossberg D, Bonoan J. Legionella and immunosuppression. Semin Respir Infect 1998; 13:128-31. PMid:9643390
- Johnson JT, Yu VL, Best MG, et al. Nosocomial legionellosis in surgical patients with head-and-neck cancer: implications for epidemiologic reservoir and mode of transmission. Lancet 1985; 2:298-300. http://dx.doi.org/10.1016/S0140-6736(85)90349-6
- Blatt SP, Parkinson MD, Pace E, et al. Nosocomial Legionnaires’ disease: aspiration as a primary mode of disease acquisition. Am J Med 1993; 95:16-22. http://dx.doi.org/10.1016/0002-9343(93)90227-G
- Franzin L, Scolfaro C, Cabodi D, Valera M, Tovo PA. Legionella pneumophila pneumonia in a newborn after water birth: a new mode of transmission. Clin Infect Dis 2001; 33: e103-4. http://dx.doi.org/10.1086/323023 PMid:11568855
- Greenberg D, Chiou CC, Famigilleti R, Lee TC, Yu VL. Problem pathogens: paediatric legionellosis--implications for improved diagnosis. Lancet Infect Dis 2006; 6:529-35. http://dx.doi.org/10.1016/S1473-3099(06)70553-9
- Yu VL, Liu Z, Stout JE, Goetz A. Legionella disinfection of water distribution systems: Principles, problems and practice. Infect Control Hosp Epidemiol 1993; 14:567-70. http://dx.doi.org/10.1086/646638
- Allegheny County Health Department. Approaches to prevention and control of Legionella infection in Allegheny County health care facilities. Pittsburgh, ABD, 1997.
- Stout JE, Muder RR, Mietzner S, et al. Role of environmental surveillance in determining the risk of hospital-acquired legionellosis: a national surveillance study with clinical correlations. Infect Control Hosp Epidemiol 2007; 28:818-24. http://dx.doi.org/10.1086/518754 PMid:17564984
- Freije MR, Barbaree JM. Legionellae control in health care facilities: a guide for minimizing risk. U.S.A: HC Information Resources, Inc, 1996.
- Akbaş E. Lejyoner hastalığının önlenmesi ve kontrolünde hastane su sistemlerinin yönetimi. Günaydın M, Öztürk R, Ulusoy S, Gültekin M eds. 5. Ulusal Sterilizasyon Dezenfek-siyon Kongresi Kitabı; 4-8 Nisan 2007; Antalya: Türkiye 2007; 334-52.
- World Health Organization. Legionella and the prevention of legionellosis. WHO. Geneva, 2007.
- Brundrett GW. Legionella and building services. Oxford: Butterworth Heinemann Ltd., 1992. PMid:1545259
- Stout JE. Culture methodology for Legionella species. Fallbrook CA: HC Special Report, 1998.
- Procedures for the recovery of Legionella from the environment. U.S. Department of Health and Human Services. Atlanta, GA: Center for Disease Control and Prevention (CDC), 1994.
- Wadowsky RM, Yee RB. Glycine-containing selective medium for isolation of Legionellaceae from environmental specimens. Appl Environ Microbiol 1981; 4:768-72.
- Ta AC, Stout JE, Yu VL, Wagener MM. Comparison of culture methods for monitoring Legionella species in hospital potable water systems and recommendations for standardization of such methods. J Clin Microbiol 1995; 33:2118-23. PMid:7559959 PMCid:PMC228346
- Lee TC, Vickers RM, Yu VL, Wagener MM. Growth of 28 Legionella species on selective culture media: a comparative study. J Clin Microbiol 1993; 31:2764-8. PMid:8253978 PMCid:PMC266009
Copyright and License
Copyright © 2013 Turkish Society of Microbiology. This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0), which permits unrestricted use, distribution, and reproduction in any medium or format, provided the original work is properly cited.